MIL-DTL-60584B (AR)
Conformance inspection by classification of characteristic
DRAWING NUMBER
PARAGRAPH
TITLE
10542946
4.3.3.4
Body Assembly
SHEET 2 OF 3
Cont.
NEXT HIGHER ASSEMBLY
10542945
CLASSIFICATION
REQUIREMENT
INSPECTION METHOD
EXAMINATION OR TEST
CONFORMANCE
PARAGRAPH
REFERENCE
CRITERIA
Major
112
Width of rotating band groove
Level IV
3.2.4
AIE
113
Width of rotating band, rear of angle
Level IV
3.2.4
AIE
114
Width of rotating band relief groove
Level IV
3.2.4
AIE
115
Location of rotating band.
Level IV
3.2.4
AIE
116
Length total (max.)
Level IV
3.2.4
AIE
117
Rotating band mechanical properties
4.4.2.4
3.5.3
4.4.2.4
118
Rotating band side wall contact
4.4.2.2
3.2.4
4.4.2.2
119
Band seating tightness
4.4.2.1.2
3.2.4
4.4.2.1
120
Sectionalized joint
4.4.3.2
3.2.4
4.4.2.2
121
Adaptor not seated for 360 degrees
Level IV
3.2.4
Visual
122
Air pressure stamp missing
100%
3.2.4
Visual
(indicating failure to pass test) (Note 1)
123
Non-destructive test stamp missing
100%
3.2.4
Visual
(indicating failure to pass test)
Note 1. Any part found without the required test stamp shall be tested to determine if the part fails the critical test. If the part fails the test it
shall be treated as a Critical Nonconformance. If the part passes the critical test it shall be treated as a Major Nonconformance.
20
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business