MIL-DTL-60584B (AR)
TABLE II - First article inspection - Continued
PART
NUMBER OF
REQUIREMENT
INSPECTION METHOD
SAMPLES
PARAGRAPH
REFERENCE
BODY ASSEMBLY
Dwg. 10542946
Examination for characteristics
10
3.2.3
4.3.3.4
Band seating tightness
3
3.5.5
4.4.3.2
Rotating Band
5
a) Side wall contact
3.5.4, 3.5.5
4.4.2.1, 4.4.2.2
b) Mechanical properties
3.5.3
4.4.2.4
Sectionalized joint
2
3.5.4
4.4.2.2
Metal Parts Assembly (after paint)
Dwg. 10542945
Examination for characteristics
35
3.2.5
4.3.3.5
Salt spray test
2
3.2.5
4.4.5
FUNCTIONAL TEST (PROVING GROUND)
Dwg. 10542945
Ballistic Testing
a) Excess pressure
15
3.7
4.4.3.5, 4.4.6 4.4.6.1
9
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.