MIL-DTL-60585B (AR)
Conformance inspection by classification of characteristic
DRAWING NUMBER
PARAGRAPH
TITLE
10542949
4.3.2.4
Plug and Casing (Alternative Design)
SHEET 1 OF 1
NEXT HIGHER ASSEMBLY
10542950
CLASSIFICATION
REQUIREME
INSPECTION METHOD
EXAMINATION OR TEST
CONFORMANC
NT
REFERENCE
E CRITERIA
PARAGRAPH
Critical
None defined
Major
101
Large Diameter
Level IV
3.2.4
AIE
102
Length of small diameter
Level IV
3.2.4
AIE
AIE
103
Radius on plug corner
Level IV
3.2.4
AIE
104
Small diameter
Level IV
3.2.4
AIE
105
Diameter of counterbore at rear of casing
Level IV
3.2.4
Depth of counterbore at rear casing
3.2.4
AIE
106
Thickness of casing wall at rear counterbore
Level IV
3.2.4
AIE
107
Level IV
108
Surface finish of radius on plug corner
Level IV
3.2.4
AIE
Minor
201
Radii or chamfers missing or incorrect
Level II
3.2.4
Visual
202
Surface finish improper
Level II
3.2.4
Visual
203
Burr
Level II
3.6
Visual
204
Foreign matter
Level II
3.7
Visual
205
Plug thickness
Level II
3.2.3
AIE
206
Evidence of poor workmanship
Level II
3.7
Visual
207
Metal defective
Level II
3.5