MIL-DTL-60585B (AR)
Conformance inspection by classification of characteristic
PARAGRAPH
TITLE
DRAWING NUMBER
4.3.2.5
Burster Case
10542949
SHEET 1 OF 2
NEXT HIGHER ASSEMBLY
10542950
CLASSIFICATION
REQUIREME
INSPECTION METHOD
EXAMINATION OR TEST
CONFORMA
NT
REFERENCE
NCE
PARAGRAPH
CRITERIA
Critical
1
Diameter of press fit surface for minimum indicated length
100%
3.2.5
AIE
Major
101
Diameter of casing at rear of transition zone
Level IV
3.2.5
AIE
102
Wall rear of transition zone
Level IV
3.2.5
AIE
3.2.5
AIE
103
Pitch diameter
Level IV
AIE
3.2.5
104
Minor diameter max.
Level IV
3.2.5
AIE
Runout of pitch diameter to press fit surface and rear of
Level IV
105
flange
3.2.5
AIE
106
Perpendicularity of front face to press fit surface
Level IV
True position of flange to press fit surface
AIE
3.2.5
Level IV
Metal defective
107
Level IV
3.5
AIE
108
109
Presence of reverse taper in press fit surface
Level IV
3.2.5
AIE
Profile of radius blend with press fit surface
110
Surface finish of press fit surface, improper
Level IV
3.2.5
AIE
111
Level IV
3.2.5
Visual/
Comparison Blocks
13